AltDrive Electric Powertrain Menu
For many heavy-duty mobile equipment applications, charging infrastructure and electrical supply are among the biggest practical challenges in electrification. The issue is not simply battery capacity — it is the rate at which energy must be delivered to the machine to sustain production cycles.
Heavy-duty mobile equipment consumes large amounts of energy over relatively short periods of time. A fully battery-electric platform must replace most energy expended with charging infrastructure, often within limited shift-change or downtime periods. As battery size and energy demand increase, charging systems require very high-power transfer rates, in the double-digit megawatts, which can create substantial demands on utility service capacity, not to mention site electrical infrastructure. Larger operations are looking to, or using, onsite storage and overnight peak shaving to supplement daytime utility draws as a strategy to supply adequate power.
Battery-electric/diesel hybrid drivetrains reduce this dependency because part of the machines’ operating energy is generated onboard. Instead of relying entirely on high-capacity external charging systems, hybrids can maintain battery charge during operation using integrated engine-generator systems. In many applications, this significantly reduces charging power requirements, infrastructure costs and grid dependency.
Full battery-electric systems require substantial charging capacity
A fully battery-electric machine relies entirely on external electrical energy. All propulsion and auxiliary loads must ultimately be supplied through charging infrastructure.
For heavy-duty applications, this often means:
- Large battery packs
- High-capacity DC fast charging
- High peak power demand
- Significant utility upgrades
- Extensive charging infrastructure planning
- Load management systems
- Additional transformers and switchgear
- Possible substation upgrades
In remote or industrial environments, electrical infrastructure may already be heavily utilized. Adding multiple high-capacity charging systems can create major grid constraints.
As battery size increases, charging time and charging power requirements also increase. Fast turnaround requirements may push systems toward very high charging rates, which can place additional stress on site electrical infrastructure.
In some applications, charging windows may not align well with production schedules. Opportunity charging during breaks or shift changes may help, but this depends heavily on operating patterns and available infrastructure capacity.
Hybrid systems reduce charging dependency
Battery-electric/diesel hybrid drivetrains reduce dependence on external charging infrastructure because onboard power generation supports battery operation during use.
Instead of relying exclusively on grid charging, hybrid systems can maintain battery state of charge through integrated engine-generator systems operating at optimized load points.
This approach can substantially reduce:
- Required charging frequency
- Charger size requirements
- Peak grid demand
- Battery size requirements
- Infrastructure capital costs
- Utility upgrade requirements
In some applications, hybrid systems may operate with little or no dedicated charging infrastructure, depending on duty cycle and operational objectives.
Other applications may use smaller charging systems to supplement onboard energy generation. This can simplify deployment in remote locations or facilities with limited available electrical capacity.
Charging infrastructure flexibility
Hybrid systems also provide more flexibility in how charging infrastructure is deployed.
Because hybrids typically require less external energy input than full battery-electric equipment, organizations may be able to:
- Use lower-power chargers
- Add infrastructure incrementally
- Avoid major utility upgrades
- Operate within existing site electrical limits
- Electrify equipment before long-term infrastructure expansion is complete
This can be particularly important for pilot programs, phased electrification projects, temporary worksites, or remote operations where utility power is constrained or unavailable.
Hybrid systems may also reduce operational risk during grid outages or unstable power conditions because the onboard power source can continue supporting machine operation.
Grid limitations can determine drivetrain strategy
In many industrial environments, available electrical infrastructure becomes a primary constraint on electrification strategy.
Even where full battery-electric equipment is technically feasible, grid limitations may make deployment impractical without major infrastructure investment.
Common constraints include:
- Limited utility service capacity
- Long utility upgrade timelines
- Remote locations
- Temporary operating sites
- Mobile operations
- High demand charges
- Limited charging windows
- Existing site electrical loads
Hybrid systems can help bridge this gap by reducing dependence on high-capacity charging infrastructure while still delivering many of the operational and emissions-reduction advantages of electrification.
Infrastructure planning should happen early
Charging and grid requirements should be evaluated early in the electrification process. Infrastructure costs, utility timelines, operational impacts and site electrical limitations can significantly affect project feasibility and overall system design.
The right solution depends on the application, duty cycle, operating environment and site infrastructure. In some cases, full battery-electric systems are the best fit. In others, a hybrid drivetrain provides a more practical balance between electrification benefits and infrastructure requirements. For a deeper dive into heavy-duty mobile equipment electrification options, look at our rationale for mines.